General Parameter (P1.) - Adtech ADTECH4 CNC Series Maintenance Manual

Table of Contents

Advertisement

11.2 General parameter (P1.)

001
002
003
007
Range
Unit
Authority
Default
Effective time
Note
004
Home mode
Range
Unit
Authority
Default
Effective time
Note
Feeding speed (mm/min)
Initial feeding speed (mm/min)
Feeding acceleration (mm/sec)
Maximum feeding speed (mm/min)
:
1~9999, 1~9999, 1~8000, 1~9999
:
mm/min, mm/min, mm/sec, mm/min
:
Operation admin
:
3000, 200, 1000, 3000
:
Instant
:
The feeding instructions G01, G02 and G03 move at the speed of F
instruction. If the F instruction isn't specified in the program, the above
instructions move at the speed set by this parameter. If the F instruction
is specified, this parameter will be invalid.
The maximum feeding speed restricts the F instruction during
processing, i.e. no matter what F is set to, the actual speed can't exceed
this parameter value. Setting this parameter will prevent the damage
caused by accidental speed programming error when transferring
processing files.
:
0~1
:
None
:
Operation admin
:
0 (program home)
:
Instant
:
0-program home
1-mechanical home
Program home is that the coordinates go to home, i.e. in place.
Mechanical home requires external detection switch to locate the home
position; while home operation, move to specified home direction at
home speed, and move back slowly after signal is detected. At this
moment, move forward slowly when the signal is disconnected, and the
home operation completes when the signal is valid again. When the servo
ADTECH4 SeriesCNC Maintenance Manual