Default
Effective time
Note
021
Axis control composite key enable
Range
Unit
Authority
Default
Effective time
Note
022
Additional panel enable
Range
Unit
Authority
Default
Effective time
Note
:
OFF/0
:
Instant
:
Used to configure whether RS232 of current system outputs debugging
information during running.
This parameter is dedicated for programmers, and users are not
recommended to enable this parameter.
If debugging information is enabled, the system performance will
deteriorate, so that it is disabled in the normal process.
If networking is enabled, this feature must be turned off, or else the
networking will crash.
:
0~1
:
None
:
Super user
:
ON/1
:
Instant
:
Used to configure whether enable the key for axis motion on the controller
panel.
This parameter is used to shield the composite function of the axis motion
control button on the NC panel when use additional panel; if additional
panel isn't used, it must be enabled or else axis movement cannot be
controlled through the buttons.
:
OFF FCNC4M FDK4A FCNC6D
:
None
:
Super user
:
OFF/0
:
Instant
:
Used to configure whether NC uses additional panel, which must match
ADT series, or compatible with the same protocol interface.
To use additional panel, the system debugging information must be
ADTECH4 SeriesCNC Maintenance Manual
Need help?
Do you have a question about the ADTECH4 CNC Series and is the answer not in the manual?