10.1 Restart
(1) In the main menu, press [Edit] to enter the program interface;
(2) Press [File] to enter the file interface;
(3) Press [Reset] and the system asks whether restart or not;
(4) Press [OK] to restart the system.
10.2 System Upgrade
The step of copying upgrade program with USB disk follows:
(1) In the main menu, press [Edit] to enter the program interface;
(2) Press [File] to enter the file management interface;
(3) Press [File] to enter the file management interface;
(4) Move cursor to the upgrade file ADTROM.BIN, select [Copy], enter ADT directory in disk D and paste;
(5) Select the second upgrade file NC_RES.NC; skip this step if the file doesn't exist. Also select Copy, enter disk D, and
paste in directory ADT.
(6) After upgrading, enter BIOS, select USB in [Boot-up mode], and restart the system to take effect.
(7) Enter System Info in Diagnosis menu to view the system version and compilation date, and check whether the upgrade is
successful.
10.3 Reset
(1) Select the edit mode;
(2) In the main menu, press [Parameter] to enter the parameter interface;
(3) Press [Management] key to enter management parameter interface;
(4) Move cursor to "006 Reset all parameters";
(5) Press [EOB], the system confirms, restores the default parameters and restarts automatically.
10.4 Parameter Backup & Restore
(1) Select the edit mode;
(2) In the main menu, press [Parameters] key to enter the parameter interface;
10.
System Maintenance
ADTECH4 SeriesCNC Maintenance Manual