Default input port configuration of 46M series (milling machine)
Wire No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Port Definition
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
IN13
IN14
IN15
IN16(XLMT-)
IN17(XLMT+)
IN18(YLMT-)
IN19(YLMT+)
IN20(ZLMT-)
IN21(ZLMT+)
IN22(ALMT-)
IN23(ALMT+)
INCOM
ADTECH4 SeriesCNC Maintenance Manual
Function
X axis zero point
Y axis zero point
Z axis zero point
A axis zero point
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
Backup input
X axis negative limit (backup IN32)
X axis positive limit (backup IN33)
Y axis negative limit (backup IN34)
Y axis positive limit (backup IN35)
Z axis negative limit (backup IN36)
Z axis positive limit (backup IN37)
A axis negative limit (backup IN38)
A axis positive limit (backup IN39)
Input common end INCOM (24V+, 12V+) connects to
internal or external power supply