Adtech ADTECH4 CNC Series Maintenance Manual page 106

Table of Contents

Advertisement

Effective time
Note
010
M code waiting time (ms)
Range
Unit
Authority
Default
Effective time
Note
011
Line number increment
Range
Unit
Authority
Default
Effective time
Note
012
System baud rate
Range
Unit
Authority
Default
Effective time
Note
013
Controller ID
Range
Unit
Authority
Default
Effective time
ADTECH4 SeriesCNC Maintenance Manual
:
Instant
:
Used to limit the maximum speed of moving the axis with hand wheel
(note: valid when P1.062 is set to 0).
:
1~9999
:
ms
:
Operation admin
:
100
:
Instant
:
Set the waiting time (unit: ms) after executing M code
:
0~64
:
None
:
Operation admin
:
0
:
Instant
:
While editing G code manually, add a line number Nxxxxx automatically
in a new line;
0 indicates that this function is disabled;
:
9600~115200
:
None
:
Operation admin
:
115200
:
Restart
:
The communication rate setting when DNC or other PC software and this
controller are in RS232 communication mode
:
1~255
:
None
:
Operation admin
:
1
:
Restart

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADTECH4 CNC Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents