029
Inp AccSpeed Mode (1: linear acceleration/deceleration 0:S curve acceleration/deceleration)
030
'S' Speed Acceleration
Range
Unit
Authority
Default
Effective time
Note
031
Home test enable after alarm
032
System home test enable
Range
Unit
Authority
Default
Effective time
Note
033
X axis diameter programming enable (L series)
Range
Unit
Authority
Default
Effective time
Note
034
Default process plane
Range
ADTECH4 SeriesCNC Maintenance Manual
:
:
:
Operation admin
:
:
Instant
:
Used to set the performance of S curve acceleration/deceleration
:
0~1
:
:
Operation admin
:
0, 1
:
Instant
:
Used to set whether prompt user to home in corresponding occasions,
ensuring that the user has performed the home operation;
If it is set to 0, the system will run directly without performing home
operation.
:
0~1
:
:
Operation admin
:
1 (L series)/0 (M series)
:
Instant
:
On lathe controller (L series), it is used to set whether the display and
programming of X axis are in radius or diameter;
:
G17,18,19
Need help?