023
Spi.Gear Numerator (CMR)
024
Spi.Gear Denominator (CMD)
Range
Unit
Authority
Default
Effective time
Note
026
Principal axis on delay
Range
Unit
Authority
Default
Effective time
Note
027
Servo principal axis ready level
028
Servo principal axis stop place level
029
Servo principal axis zero speed in place level
030
Servo principal axis speed arrival level
Range
Unit
Authority
Default
ADTECH4 SeriesCNC Maintenance Manual
variable frequency rotation corresponding to analog 10V, and transfer the
rotation directly later, while the controller will output corresponding
analog voltage according to linear scale automatically.
:
1~65535
:
None
:
Operation admin
:
1
:
Instant
:
If the principal axis has gear position, please set the hardware gear ratio
to this parameter, which hasn't been used in standard version, but may be
used in certain special conditions.
:
0~10000
:
ms
:
Operation admin
:
0
:
Instant
:
Set the delay before next action or operation after forward or reverse
rotation of the principal axis.
:
0~1
:
None
:
Operation admin
:
0