B axis start rate (mm/min)
C axis start rate (mm/min)
004
X axis acceleration (Kpps)
Y axis acceleration (Kpps)
Z axis acceleration (Kpps)
4 axes acceleration (Kpps)
B axis acceleration (Kpps)
C axis acceleration (Kpps)
Range
Unit
Authority
Default
Effective time
Note
005
X axis positive soft limit (mm)
X axis negative soft limit (mm)
Y axis positive soft limit (mm)
Y axis negative soft limit (mm)
Z axis positive soft limit (mm)
Z axis negative soft limit (mm)
4 axes positive soft limit (mm)
4 axes negative soft limit (mm)
B axis positive soft limit (mm)
:
1~9999, 1~9999, 1~8000
:
mm/min, mm/min, mm/sec
:
Operation admin
:
3000, 200, 1500
:
Instant
:
This parameter is the trapezoid acceleration/deceleration setting used for
GOO instruction
About start speed, 1-2 rotation motor speed is recommended for step
motor; as above, the machine tool moves 5mm when the motor rotates
one cycle, and the speed is 5-10mm/sec (300-600mm/min). For servo
motor, the start and stop shouldn't have vibration. If this speed is too
high, it will cause vibration during motion, and the step motor will be out
of step.
Parameters affected by the acceleration and start speed include manual
speed, home speed and other non-interpolation motions;
ADTECH4 SeriesCNC Maintenance Manual
Need help?
Do you have a question about the ADTECH4 CNC Series and is the answer not in the manual?