Range
Unit
Authority
Default
Effective time
Note
032
X axis encoder pulse logic direction
Y axis encoder pulse logic direction
Z axis encoder pulse logic direction
4 axes encoder pulse logic direction
B axis encoder pulse logic direction
C axis encoder pulse logic direction
Range
Unit
Authority
Default
Effective time
Note
033
X axis home deceleration speed
Y axis home deceleration speed
Z axis home deceleration speed
4 axes home deceleration speed
B axis home deceleration speed
ADTECH4 SeriesCNC Maintenance Manual
:
0~1
:
None
:
Super admin
:
1
:
Instant
:
When mechanical home mode is selected, this parameter determines
whether external deceleration switch should be searched. If this parameter
is set to 0, and P2.015 (servo Z phase enable) is also set to 0, the home
mode sets current point as the home directly in mechanical mode.
0: No
1: Yes
:
0~1
:
None
:
Super admin
:
0
:
Instant
:
If the logic direction obtained by the encoder is reverse to the actual
motion direction of the axis, please set this parameter.
0: Positive
1: Negative