025
Auto-zero mode configuration (BIT)
Range
Unit
Authority
Default
Effective time
Note
026
Arc Acc.for Radii
027
Arc Acc.for Speed
Range
Unit
Authority
Default
Effective time
Note
028
Pretreatment Code Set
Range
Unit
Authority
Default
Effective time
Note
ADTECH4 SeriesCNC Maintenance Manual
Output signal follows the hertz specified by P1.024 in working state, and
used for oil supply devices. If it is set to 0, the system will keep low
output level.
:
:
:
Operation admin
Z – XYABC
:
:
Instant
:
Set the zero sequence of each axis; up to three sections can be set.
:
:
Coefficient
:
Operation admin
:
50, 100
:
Instant
:
Used to restrict the arc processing speed automatically. This parameter is
valid in pretreatment mode.
The bigger the radius coefficient is, the lower the arc speed is.
The bigger the acceleration coefficient is, the higher the arc speed is.
:
100~5000
:
Instruction line
:
Operation admin
:
500
:
Instant
:
Set the pre-reading instruction lines; if the pretreatment processing
pauses and pre-reads, please increase this value to pre-read more
instructions.