Range
Unit
Authority
Default
Effective time
Note
057
System home ON
Range
Unit
Authority
Default
Effective time
Note
058
Spindle brake delay (ms)
Range
Unit
Authority
Default
Effective time
Note
059
Rotation axis speed optimization feature (this parameter is invalid currently)
Range
Unit
Authority
Default
Effective time
ADTECH4 SeriesCNC Maintenance Manual
:
OFF ON
:
None
:
Operation admin
:
OFF
:
Instant
:
Enable and set this parameter to ON to jump to line N of X cycle of M98
instruction and start processing.
:
No, ask, auto
:
None
:
Operation admin
:
No
:
Instant
:
Ask: when the system is restarted, it asks whether to execute home
operation; press the [EOB] button to execute.
Auto: when the system is restarted, it executes home operation
automatically.
:
0 ~ 60000
:
sec
:
Operation admin
:
1000
:
Instant
:
Used to set the delay between actions of the principal axis brake switch
:
:
:
Operation admin
:
:
Instant
Need help?