3.12.1.1 NOTIFY ALARMs
through
3.12.1.2 Last Field
3-32
8061SW-02 - User's guide and Data Display
Notification of alarms via SMS will be sent to both mobile phones indicated.
For each alarm a string is sent; for full list see ?STA command on the pag.
5-13.
Notification via modem will be sent to the first number that answers the call.
When both Modem and SMS notifications are enabled, priority is given to
the Modem.
For each one of the 7 alarms there is a bar in the in control window that
shows by its color the current status of the respective alarm, regardless of
whether notice via modem or SMS is enabled or disabled:
RED: alarm condition activated;
GREEN: alarm not active.
Displays the field averaged in the latest minutes as set in the Averaging
Period field. This field is refreshed each time you click the Last field button.
AMS-8061 can be remotely queried for this value at any time from a
mobile phone by sending the following SMS message to the station: