L3Harris NARDA AMS-8061 User Manual page 177

Area monitor selective
Table of Contents

Advertisement

Command
Description
Full
?IDNF
authentication.
The reply displays the brand (Nsts), Station model
and
firmware
calibration date, originate call (ON, OFF or NET if
set to GPRS/FTP), time and switch on interval
Modem 1, SMS Report (ON or OFF), time and
interval Modem 2, Alarm mask.
Format:
IDN=identifier;Nsts,AMS-8061;R.rr MM/YY;
Serial Number; Date of calibration;
ON|OFF|NET HH:mm (Xq) each Yh;ON|OFF
HH:mm (Zq) each Wh;ALARM;
Where:
identifier is the name of the Station, stored by
SIDN command.
R.rr is the release and MM/YY the date of the
internal firmware.
Serial Number is written in factory.
Date of calibration is the last calibration date, as
dd.MM.YY.
Originate Call can be ON, OFF or NET to indicate
the Station call mode.
HH:mm (Xq) each Yh shows the Modem status for
first interval, same as ?TSM command.
Send Report can be ON or OFF to indicate if the
SMS report sending is active or not.
HH:mm (Zq) each Wh shows the Modem status
for second interval, same as ?TSS command.
ALARM is a symbolic string to show the alarms
states, as for ?ALR command
.
The argument PASSWORD is always necessary,
as a security authentication, when a password is
set in the remote Station and any wireless
connection is used.
Via SMS, it is advisable to send the ?IDN
command,
authentication.
Please look at the SPSW command to find
information about how to save the password in the
Station.
Last mean value query command.
?LFA
The answer displays the mean value in the current
unit, calculated along the set averaging time (set by
the SAVG command)
Identifier
request
release,
serial
instead,
to
make
Example
with
password
Example: #SM?IDNF*
Response:
IDN=democisano;Nsts,AMS-8061;
number,
last
B.10 09/15;000WX50802;
13.08.15;NET 12:15 (4q) each
01h;ON 17:10 (1q) each 24h;--------
----;
Another Example: #SM?IDNF
PASSWORD* #SM?BAT*
Response:
IDN=democisano;Nsts,AMS-8061;
A.46 08/15;000WX50802;
21.07.15;NET 12:15 (4q) each
01h;ON 17:10 (1q) each 24h;--------
----;BAT=13.07
Where:
democisano is the Station identifier
Nsts is the narda brand
AMS-8061 is the model
A.46 is the fw release and
08/15 means August 2015
000WX50802 is the Station's S/N
21.07.15 means July 21
is the latest calibration date
NET 12:15 (4q) each 01h means
that the Station is set to call via
GPRS/FTP, at 12:15, remaining on
for 4/4 of hour each hour (that is to
say, permanently on)
ON 17:10 (1q) each 24h means that
the SMS Report is sent at 17:10 and
the Station Modem remains on for ¼
of hour each 24 hours (1 day)
------------ means no Alarm is active
BAT=13.07 is the reply to the
the
password
second command and means the
internal battery voltage is 13.07 V
The reply to an incorrect password
is: DENIED
Example: #SM?LFA*
Response: LFA=0.46
It means 0,46 V/m is the mean value
for last rate interval.
SMS Messages and Commands
th
2015 and
5-9

Advertisement

Table of Contents
loading

Table of Contents