L3Harris NARDA AMS-8061 User Manual page 79

Area monitor selective
Table of Contents

Advertisement

Schedule for SMS divided into:
Telephone number
Time (HH:mm)
Stand by (Q) indicated in number of quarters of an hour; this value
affects battery duration
Every (H)
Send REPORT
Up to ten mobile phones can be programmed.
Both phones will receive the daily report.
For each alarm a string is sent to mobile phones programmed; for full
list see ?STA command on the pag. 5-13.
Get DATA divided in:
Start with the subcommands
-
Since Last Time
-
Date & Time
The starting date must be coherent with the Rate selected and not later
than the Stop date.
If measurement results related to a period longer than the capacity of
the memory, or data no longer contained in the memory (because
overwritten) are requested, the software will show a warning message.
Stop with the subcommands:
-
Up to NOW
-
Date & Time
The Stop date must be later than the Start date otherwise an error
message will appear.
Recall
It is used to start downloading results acquired in the period from Start
to Stop settings.
Get Recent Events
This command manually recalls all the events that have not yet been
downloaded, and appends them at the end of the relative file.
This command shall be considered the manual alternative to the option
Autoload Events.
Get All Events
The command manually recalls all the events available on the station
and appends them at the end of the relative file. Though this does not
create any problems, no control of redundancy is made, so repeatedly
selection of the command may lead to repetitive information.
Clear Station
Cancels the internal memory of the station linked.
If there are data which have not been transferred to a PC yet, the
function is automatically disabled.
Auto Clear
Enables total cancellation of the data in the station memory after
complete downloads. When this option is enabled, after every complete
download up to the time and date indicated in Get Data Stop, the
software sends a request of complete cancellation (SCAM) of the data
in the memory and, if there are no errors, the request is accepted by the
station, which clears its memory. Obviously, once the data have been
cancelled they cannot be recalled anymore.