L3Harris NARDA AMS-8061 User Manual page 195

Area monitor selective
Table of Contents

Advertisement

55
GPRS
1
Interval
56
Prxon
1
57
Reserved
1
58
SMS
2
Sched
60
SMS
1
Ton
61
SMS
1
Interval
62
SMS
1
Xon
63
Reserved
1
64
Reserved
2
66
Reserved
1
67
Reserved
1
68
Reserved
1
69
Reserved
1
70
Ethernet
2
Sched
72
Reserved
1
73
Ethernet
1
Interval
74
Ethernet
1
Schedule
Active
75
Reserved
3
78
StartFreq
4
82
StopFreq
4
86
Reserved
1
87
Reserved
1
Unsigned char
This parameter represents the interval between GPRS
connections (starting from the first connection which is
done at Appoint). It is expressed in hours.
Unsigned char
This is the flag for connecting to GPRS upon alarms.
If bit 0x01 is '1' and one or more unmasked alarm is set,
a GPRS connection is done as it was for schedule.
Note that bit 0x08, the GPRS Flag, must always be ON.
Unsigned char
None
Unsigned int
This parameter represents the scheduled time for SMS
schedule of the day. It is expressed in minutes elapsed
since midnight.
For example the schedule 12:30 would be (12*60)+30
=750
Unsigned char
This parameter represents how long the GSM remains in
stand-by mode after a SMS connection. It is expressed
in quarters of hour.
Unsigned char
This parameter represents the interval between SMS
connections (starting from the first connection which is
done at Appoint). It is expressed in hours.
Unsigned char
This is a double flag for sending a report and alarm on
SMS.
If bit 0x01 is '1' and one or more unmasked alarm is set,
a "ALR" like SMS is sent to the number stored in the
SMS telephone directory.
If bit 0x02 is '1' a "RPT" like SMS is sent to the number
stored in the SMS telephone directory.
Unsigned char
Reserved
Unsigned int
Reserved
Unsigned char
Reserved
Unsigned char
Reserved
Unsigned char
Reserved
Unsigned char
Reserved
Unsigned int
This parameter represents the scheduled time for
Ethernet schedule of the day. It is expressed in minutes
elapsed since midnight.
For example the schedule 11:08 would be (11*60)+8
=668
Unsigned char
Reserved
Unsigned char
This parameter represents the interval between Ethernet
connections (starting from the first connection which is
done at Ethernet Sched). It is expressed in hours and it
can be either 12 or 24.
Unsigned char
This parameter enables/disables Ethernet Scheduling
When "Ethernet Schedule Active" = 0x02 the Ethernet
activity is regulated by "Ethernet Sched".
Instead, when "Ethernet Schedule Active"
Ethernet is OFF
Unsigned char
Reserved
float
Little
representing the start frequency of the first band and it is
expressed in Hz.
float
Little
representing the Stop frequency of the first band and it is
expressed in Hz.
Unsigned char
Reserved, it must be 0
Unsigned char
Endian
32bit
IEEE
Endian
32bit
IEEE
SMS Messages and Commands
is
0
the
floating
point
number
floating
point
number
5-27

Advertisement

Table of Contents
loading

Table of Contents