3.6.8 Autoload Events
3.7 Data management
3.7.1 Filing data
3-22
8061SW-02 - User's guide and Data Display
The AMS-8061 Area Monitor System can save a certain number of events
in the permanent memory of the station, so as to ensure traceability
(independent from the operations of the control center) with regard to the
settings and main activities of the station. These events can be downloaded
from the station, displayed in text format and copied into the mass memory
of the control center to keep updated the station history.
The option Autoload Events facilitates this task as, every time the station
is contacted, it is automatically asked for all events not already
downloaded. It is important to know that to increase the reliability in case of
sudden interruption of the call, at each connection the events request is
made at two separate times. The first request is made at the end of
reception of the setting parameters and the second is made immediately
before receiving the hang-up command. This ensure that all events are
downloaded even in case of problems during the connection (which may be
interrupted before all operations have been completed) and at the same
time ensures that all events recorded after the connection in progress will
also be received.
The Data Exchange key is used to file the data saved and import them
later on to other control centers.
Selecting this key the following options are displayed:
When exporting data, after the selection of the type of support, the data are
automatically saved in a directory called 8061_EXP.
Select Selective storing to enable the program to select which data to
export, as shown in the figure below, otherwise all the data found will be
exported.
Exported data can be easily imported by the 8061SW-02 control software
installed in a different PC by selecting device containing exported data and
clicking the "Import" button.
Importing data creates a directory which name correspond to the
Station Identifier (Name) selected from the station list before
exporting data.
If not already present, a new station, with the same Station Identifier
(Name) should be added to the station list in order to be able, through
the calendar, to display measurement results.