3.7.2 Exporting data
POSTAZIONEserialnumber_FROM_YYYY-MM-DD_HH-mm_TO_YYYY_MM_DD_HH-mm.TXT
The Data Export function creates text files and, if enabled, .bmp files related
to the time range specified by the user:
After selecting the desired time range (From date – To date) click the Export
button to create, in the AUTOFILE directory, the following text files:
A text file reporting the events relative to the control center in the
selected period. This file is saved as AUTOFILE\PC_LOG.TXT;
A text file reporting the events relative to the station in the selected
period. This file is saved as AUTOFILE\8061_LOG.TXT;
A text file and, if enabled, a .bmp file, reporting the data records (field
strength, battery voltage, temperature, alarms, etc.) formatted as in
the menu for the selected range. Indeed, the file is the same one
produced automatically with the option Auto ASCII file except that,
instead of referring to the period downloaded, the period can be
specified manually. The file name appears in the following format:
On opening the Data Export window, the initial date and time shown by
default are the date and time of the latest export of the station: it is therefore
possible to export in a very easy way all the data collected in the correct
chronological sequence without having to remember the latest operation.
The maximum time interval that can be processed by the Data Export
function is one month.