Wiring The Relay Output - ProMinent DULCOMETER PH-501 Assembly And Operating Instructions Manual

Compact controller
Table of Contents

Advertisement

WIRING (continued)
Wiring the Relay Output: Switch Tek™ requires 12 36 VDC (30 VDC max. for LZ12 series) power to operate
the sensor and switch the relay. All illustrations below identify a Dry switch state as the normal position of the
relay.
Switching a Normally Open DC Load:
The Red wire connects to Positive (+) of the power
supply and the Black wire connects to Negative ( ).
The LOAD can be attached to either the Green or
White wires. Complete the circuit by connecting the
Green to (+) VDC power or White to ( ) VDC power
(see illustration below).
Sensor Power
[RED & BLK wires] / 36 VDC Max.
5 ±1mA Dry / 22 ±1mA Wet
Switching a Normally Open AC Load:
The Red wire connects to Positive (+) of the DC power
supply and the Black wire connects to Negative ( ).
The LOAD can be attached to the Green wire and the
Hot of the VAC power. Connect the White to the
Neutral of the VAC power (see illustration below).
Sensor Power
[RED & BLK wires] / 36 VDC Max.
5 ±1mA Dry / 22 ±1mA Wet
14 of 20
Switching a Normally Closed DC Load:
The Black wire connects to Positive (+) of the power
supply and the Red wire connects to Negative ( ). The
LOAD can be attached to either the Green or White
wires. Complete the circuit by connecting the Green
to (+) VDC power or White to ( ) VDC power (see
illustration below).
Relay Rating
[GRN & WHT wires] / 60 VA
Switching a Normally Closed AC Load:
The Black wire connects to Positive (+) of the DC
power supply and the Red wire connects to Negative
( ). The LOAD can be attached to the Green wire and
the Hot of the VAC power. Connect the White to the
Neutral of the VAC power (see illustration below).
Relay Rating
[GRN & WHT wires] / 60 VA
LO900002
Step Seven
E-1270
Rev A