Location
P-801 – Backwash Pump
-General Condition (Temperature,
Unusual Noises or Vibrations,
Cracks, Leaks, Loose Hardware,
Etc.)
- Pump Performance (Gauges,
Speed, Flow)
B-301/302 , 601/602 – EQ and
Membrane Tank Blowers
-Clean electrical motor and keep
ventilation openings clear
MECHANICAL
-Check inlet filter. Clean or
& PROCESS
replace as necessary.
B-501/502 – Aeration Tank
Blowers
-Clean electrical motor and keep
ventilation openings clear
- Check V-belts for tightness
- Check and add fresh oil as
required to maintain proper level.
- Change blower oil.
-Check inlet filter. Clean or
replace as necessary.
SCR-101/102
-Inspect inspecting the unit for
blockages and general cleaning.
Inspection doors are located on
the cover guard and screen
body. Washing the screen with
high water pressure may be
necessary.
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
Item
1291 California Avenue, Brockville, ON K6V 5W3
(800) 420-4056 / www.newterra.com
X
X
X
X
X
X
X
X
newterra ltd.
Comments
Submersible
pumps contain oils
which becomes
pressurized and
hot under operating
conditions - allow
2½ hours after
disconnecting
before attempting
service.
In accordance with
vendor manual in
Appendix E
In accordance with
vendor manual in
Appendix E
Semi-annual
94