5.9 Post-Anox Tank (TNK-551) Module
The schematic of the Post-Anox Tank (TNK-551) is located on the AERATION HMI screen and
shown below.
5.9.1 Function
Mixed liquor flows by gravity from the second aeration tank (TNK-502) to the post-anoxic tank
(TNK-551) for final denitrification polishing. In the post-anoxic tank, there are minimal dissolved
influent organics to drive the denitrification process. As such, an external carbon source in the
form of Micro C is dosed (by P-6103) to supplement the organics and drive the denitrification
process.
5.9.2 Inputs
None
5.9.3 Setpoints
None