6.2.1.2 MBR – Recommended Biological Operational Conditions
Parameter
MLSS (mg/L)
Temperature (°C)
pH (s.u.)
Aeration Tank, DO
(mg/L)
Viscosity (mPa-s)
Aeration Tank to
Anoxic Tank
Recirculation
Membrane Tank to
Aeration Tank
Recirculation
F:M (kg BOD/kg
MLSS/d)
F:M (kg COD/kg
MLSS/d)
SRT
Process Troubleshooting Guide is presented in Section 7 of this O&M Manual.
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
Recommended
Range
8,000 –
10,000
15,000
15 - 35
10 – 35
6.8 - 8.5
6.0 – 9.0
≥ 2.0
1.0 – 8.0
Not applicable
0 – 300
200 –
400%
500%*
400%
200 – 600%
0.1
0.03 – 0.2
0.15
0.05 – 0.3
> 15
12 – 50
1291 California Avenue, Brockville, ON K6V 5W3
(800) 420-4056 / www.newterra.com
Notes
Never operate the membranes if MLSS
< 3,000 mg/l. Sludge wasting should be
undertaken as required to maintain
target MLSS
Avoid sudden changes in temperature.
Minimum operating temperature is 15 °C
Membrane module can handle a change
in pH, however it is recommended to
keep pH between 6.8 - 8.5
This can be maintained by adjusting the
volume of air supplied to the aeration
tank
Only applies if an anoxic tank is
included.
*The recycle ratio is a function of
effluent NO
-N/TN limit
3
F:M = [Flow (m
3
/d) x BOD conc (mg/l)] /
3
[Process volume (m
) x MLSS conc
(mg/l)]
F:M = [Flow (m
3
/d) x BOD conc (mg/l)] /
[Process volume (m
3
) x MLSS conc
(mg/l)]