g. Slowly add 25% of the supplied heterotrophic dry seed bacteria through the view
port). The following quantities in Table 1 are typically shipped with standard camp
systems, if the current system is not on this list please consult with a Process
Engineer:
Table 1 - Seed bacteria quantities per standard camp model
Standard Camp Model
h. Turn aeration tank blowers to "AUTO".
i.
Continue adding raw wastewater and dry seed bacteria according to the schedule
outlined in Table 2 below:
Table 2 - Dry seed and wastewater dosing schedule
Day
1
2
3
4
5
6
7
j.
As the aeration tank fills, continue to adjust the positioning of the DO and pH probes
accordingly.
2. Once the aeration tank is full (liquid level >80%) the remaining equipment in the system
can be started. Turn all equipment (except sludge wasting/processing equipment) to
"AUTO". Set the permeate flow rate at a value to achieve a flux of 6.5 lmh initially.
Convert flux (lmh) to flow rate (lpm) as follows:
**** Verify the membrane cassette model – MCXL2 = 8 m
3. Continue increasing the flux rate everyday according to the schedule in below.
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
Dry Bacteria (Bioremove
5190) (lbs)
50 Man
100 Man
300 Man
600 Man
1000 Man
Daily Wastewater
Flowrate (% of
Aeration Tank
Volume)
30%
10%
10%
15%
15%
15%
5%
1291 California Avenue, Brockville, ON K6V 5W3
Nitrifying Bacteria
(Bioremove 5895) (lbs)
50
50
75
75
100
Aeration Tank Fill
Level (%)
(% of Total Supplied)
30%
40%
50%
65%
80%
95%
100%
2
newterra ltd.
(800) 420-4056 / www.newterra.com
10
10
20
20
30
Dry (heterotrophic)
Seed to be Added
25%
20%
15%
10%
10%
10%
10%
of surface area