b. TNK-601 holds approx. 8 m3 or 8000L.
7. Turn on air scour for 2 min to mix the solution and turn it off during membrane soak.
8. Allow membranes to soak for 1 to 2 hours.
9. Drain spent solution.

7.3.2.3 Step 3 - Cleaning with Sodium Hypochlorite (NaOCl)

1. Turn off air scour
2. Confirm that the membrane tank (TNK-601) has been cleaned and refilled with water (Section
7.3.2.1).
3. Add NaOCl into the membrane tank to a concentration of 500 mg/L as free chlorine (max.
1,000 mg/L). Turn on air scour for 2 min to mix the solution and turn it off during membrane
soak.
Volume of NaOCI required can be calculated with the following formula:
. 0
05
V
m
V
x
C
s
: Volume of membrane tank - TNK-601 holds approx. 8.0 m3 / 8000L.
: NaOCI concentration (%)
: Volume of NaOCl required (m3 or Litre)
4. Keep the membranes soaked for 8 to 12 hours in the NaOCl solution (longer soak time
required if severe fouling is evident).
5. Drain spent NaOCl solution.
6. Rinse membrane filter thoroughly with potable water by filling and draining the entire tank.
Rinse waters are drained to the sump/recycle back to the headwork.
7. Repeat step 6 to ensure all NaOCl has been thoroughly removed.
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
1291 California Avenue, Brockville, ON K6V 5W3
(800) 420-4056 / www.newterra.com
newterra ltd.
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

986214

Table of Contents