ProMinent DULCOMETER PH-501 Assembly And Operating Instructions Manual page 560

Compact controller
Table of Contents

Advertisement

Location
Inspect and maintain valves &
fittings for leaks.
Membrane in-situ cleaning
Remove membrane module for
mechanical cleaning and
inspection
Remove, inspect and maintain
diffusers in aeration and
membrane tanks
MECHANICAL
& PROCESS
P-201/202, 301/302, 401/402,
501/502, 553/554, 551/552 – Price
Pumps
-General Condition (Temperature,
Unusual Noises or Vibrations,
Cracks, Leaks, Loose Hardware,
Etc.)
- Pump Performance (Gauges,
Speed, Flow)
-Clean electrical motor and keep
ventilation openings clear
P-701/702 – Permeate Pumps
-General Condition (Temperature,
Unusual Noises or Vibrations,
Cracks, Leaks, Loose Hardware,
Etc.)
- Pump Performance (Gauges,
Speed, Flow)
-Clean electrical motor and keep
ventilation openings clear
-Do Not let the pump run dry!
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
Item
1291 California Avenue, Brockville, ON K6V 5W3
(800) 420-4056 / www.newterra.com
X
X
2-4 hours
X
Drain membrane
tank. Roll out
membrane
cassette. Remove
membranes and
inspect. (1 -2 days)
X
This involves a
complete draining
of tanks (1-2 days).
In accordance with
vendor manual in
Appendix E
X
See vendor manual
at Appendix E.
X
See vendor manual
at Appendix E.