6.2.2.1 Filterability Test

The objective of the filterability test is to evaluate the condition of the working biomass. This is
assessed by measuring the volume of filtrate passing through the filter paper. If filtrate is greater
than 10 mL/10 min, then biomass filterability is acceptable; however, if it is less than 10 mL/10
min, modifications to the plant operating condition are required to prevent premature membrane
fouling. See the Membrane Fouling Troubleshooting Guidelines table in Section 7.6.1 to
determine the cause of the low filterability and how to correct operation to improve the
filterability.
Laboratory Glassware and Filter Paper
Apparatus:
Filterability Kit is distributed by newterra ltd (Part # 24146).
Measurement Procedure:
1. Pleat filter paper by folding in half, quarters etc.
2. Line the funnel with pleated filter paper and place the funnel in the graduated cylinder.
3. Collect 50 mL of activated sludge sample in a beaker and stir.
4. Pour the 50 mL sample into the funnel.
5. Start timer when the first drop of water filtered through the filter paper.
6. After 10 minutes of filtration, record the level of filtrate in the graduated cylinder.
newterra O&M Manual
85
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.

Advertisement

Table of Contents
loading

This manual is also suitable for:

986214

Table of Contents