Filterability (FT)
> 10 ml
5 - 10 ml
< 5 ml
6.2.3 Suggested Test Equipment for Monitoring
The following test equipment's will assist in the monitoring of the MWWTP but are not provided
with the system.
6.2.3.1 Filterability - Laboratory Glassware and Filter Paper
Apparatus:
Filter paper - AMD Manufacturing, Part Number NO5C 18.5CM or equivalent;
Funnel (75 mm diameter recommended);
50 mL graduated cylinder - Cole-Parmer Graduated Cylinder, Part Number RK-06134-67
or equivalent;
Beaker (min 100 ml size) and stir rod
Watch with seconds display or equivalent
newterra O&M Manual
© 2017 by newterra, ltd.
All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of newterra ltd.
Action
Excellent, no action req'
Tweak process operation
Process adjustment req
1291 California Avenue, Brockville, ON K6V 5W3
(800) 420-4056 / www.newterra.com
State of urgency
Contact newterra ltd.
newterra ltd.
86