ATLAS 550 System Manual
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Severely Errored Framing Seconds (SEFS)
parameter. The default value is 17 for an approximate BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Unavailable Seconds (UAS) parameter. The
default value is 10 for an approximate BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Controlled Slip Seconds (CSS) parameter.
The default value is 4 for an approximate BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Path Code Violations (PCV) parameter, when
the Line Type is Super Frame (AT&T D4 format) DS1. The default value is 691 framing errors for an
approximate BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Path Code Violations (PCV) parameter, when
the Line Type is Extended Super Frame DS1. The default value is 132,960 CRC errors for an approximate
BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Line Errored Seconds (LES) parameter. The
default value is 648 for an approximate BER level of 10E-5.
S
C
> SNMP > DS1 T
YSTEM
ONFIG
Write security: 3; Read security: 5
The DS1 performance monitor Threshold Value for the Total Line Code Violations (LCV) parameter. The
default value is 133,400 for an approximate BER level of 10E-5.
S
C
> SNMP > ASP E
YSTEM
ONFIG
Write security: 0; Read security: 0
Configures the ADLP list used when accepting incoming traps from remote ADTRAN TSU 100 Series or
ISU 512 units. For a trap to be recognized and sent to the network management station (NMS) listed in the
field, the remote unit must be listed in the
T
D
RAPS
ESTINATION
and
A
ADLP P
DDRESS
ASSWORD
61200305L2-1B
P
T
OTAL
ERF
P
T
OTAL
ERF
P
T
OTAL
ERF
P
T
OTAL
ERF
P
T
OTAL
ERF
P
T
OTAL
ERF
P
T
OTAL
ERF
C
NDPOINT
OMMUNITIES
parameters must be configured.
© 2004 ADTRAN, Inc.
Section 4 User Interface Guide
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
> T
HRESHOLDS
OTAL
ASP E
C
NDPOINT
OMMUNITIES
SEFS T
HRSH
UAS T
HRSH
CSS T
HRSH
PCV T
(D4)
HRSH
PCV T
(ESF)
HRSH
LES T
HRSH
LCV T
HRSH
list. The
ADLP
87
Need help?
Do you have a question about the Atlas 550 and is the answer not in the manual?