Section 1 System Description
3.

OPTION MODULES

Each of the following ATLAS 550 option modules is hot-swappable:

T1/PRI Network Interface Module (P/N 1200307L1/L2)

E1/PRA Network Interface Module (P/N 1200308L1)

Modem Management Network Module (P/N 1200341L1)
BRI DBU Network Interface Module (P/N 1200327L1)
Dual Nx 56/64 Option Module (P/N 1200311L1)
Dual USSI Option Module (P/N 1200754L1)
Dual/Quad T1/PRI Option Module (P/N 1200314L1/L2 and 1200755L1/L2)
Quad Basic Rate ISDN (U-Interface) Option Module (P/N1200315L1)
Quad Basic Rate ISDN (S/T-Interface) Option Module (P/N1200764L1)
Octal/Quad FXS Option Module (P/N 1200309L1/1200328L1)
Octal/Quad FXO Option Module (P/N 1200310L1/1200329L1)
Octal E&M Option Module (P/N 1200313L1)
Octal Ethernet Switch Option Module (P/N 1200766L1)
Resource Host Module (P/N 1200324L1)
4, 8, 16, 24 Channel Voice Compression Resource Modules (P/N 1200312Lx)
32 Channel ADPCM Resource Module (P/N 1200752L1)
Nx 56/64 BONDing Resource Module (P/N 1200326L1)
Legacy Data Option Module (P/N 1200342L1)
NxT1 HSSI/V.35 Option Module (P/N 1200346L2)
Replacing an option module with a different module type will result in configuration loss.
Each option module contains a variety of performance and alarm status information. Although default
values reflect the most common configurations, several features of each module are user-configurable. All
option modules contain an extensive self-test as well as tests designed for the technology they incorporate.
T1/PRI Network Interface Module (P/N 1200307L1/L2)
The T1/PRI Network Interface Module provides one channelized T1 or PRI interface. This interface
operates in DS-1 or DSX-1 mode and can deliver timing for the system. The ATLAS 550 domestic system
(P/N 1200305L2) ships with one installed T1/PRI Network Interface Module.
E1/PRA Network Interface Module (P/N 1200308L1)
The E1/PRA Network Interface Module provides one channelized E1 or PRA interface using either a
standard DB-15 or BNC connector. This interface operates in CCS or CAS signaling mode and can deliver
timing for the system. The ATLAS 550 international system (P/N 1200306L2) ships with one installed
E1/PRA Network Interface Module.