SYSTEM EVENTS

The following tables provide a listing of ATLAS system events. This includes tables of events for each
category, according to the order they appear in the
Console Log String
"-24 V Power Failure Cleared"
"-24 V Power Failure"
"-58 V Power Failure Cleared"
"-58 V Power Failure"
>70 Internal Temperature Warning Cleared
>70C Internal Temperature Warning
>85 Internal Temperature Warning Cleared
>85C Internal Temperature Warning
ACO Switch pressed
Cold
External Alarm Cleared
External Alarm Detected
Firmware invalid
Firmware update completed
Firmware update failed
Login Failure
Module Found
Module Not Responding
Not responding to programming
SNMP Authentication Failure
System Configuration Uploaded
Timing source changed to Backup
Timing source changed to Internal
Timing source changed to Primary
a
Generated five seconds after the completion of system initialization.
b
Three consecutive logins were attempted and failed.
c
Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP
communities list but with a community name that does not match the community name defined in the SNMP
communities list.
61200305L2-1B
E
VENT
Table 1. System Controller Events
Category
CRITICAL
-24 V power supply is functioning normally again
CRITICAL
-24 V power supply is not operating properly
CRITICAL
-58 V power supply is functioning normally again
CRITICAL
-58 V power supply is not operating properly
CRITICAL
Internal system temperature has cooled below 70
CRITICAL
Internal system temperature is greater than 70
CRITICAL
Internal system temperature has cooled below 85
CRITICAL
Internal system temperature is greater than 85
MINOR
ACO switch pressed
NORMAL
System cold start
MINOR
External alarm cleared
MINOR
Alarm detected on External Alarm Monitor
CRITICAL
Corrupted firmware
INFO
Flash download successful
CRITICAL
Flash download failed
MINOR
Console login failure
INFO
Module found
WARNING
Module removed or not responding
MINOR
Unable to program module
INFO
SNMP authentication failure
CRITICAL
ATLAS configuration file loaded into the system and
activated
MINOR
The primary source is not backup valid
MINOR
Neither the primary nor the backup are valid
MINOR
The timing source changed to primary
© 2004 ADTRAN, Inc.
Section 7 System Event Logging