Download Print this page
ADTRAN ATLAS 550 Manual

ADTRAN ATLAS 550 Manual

Dc system
Hide thumbs Also See for ATLAS 550:

Advertisement

Quick Links

ATLAS 550 (DC SYSTEM)
Quick Start Guide
Reviewing the Front Panel
Craft Interface
Connecting to the ATLAS 550
To access the terminal menus and management features of the ATLAS 550,
connect the unit to a VT100 terminal (or VT100 terminal emulator) via the
C
interface on the front panel or the A
RAFT
Perform Steps Below in the Order Listed:
1. Configure a VT100 terminal (or terminal emulation software) with the
following settings:
Data Rate:
9600 baud
Data Bits:
8
Parity Bits:
None
Stop Bits:
1
Flow Control:
None
If the terminal has a parallel setting, disable it and use serial.
2. Connect an appropriate cable into the ATLAS 550 C
connect to the VT100 terminal.
3. Initiate a terminal session and the L
password is password. (Passwords in the ATLAS 550 are case sensitive.)
Quick Start Guide, 61200550L2-13A, June 2003
ACO
System Status
Network
Switch
LEDs
Module LEDs
interface on the rear panel.
DMIN
or A
RAFT
DMIN
screen displays. The default
OGIN
Technical Support 1-888-4ADTRAN (1-888-423-8726)
For more detailed documentation, visit us online at
Option Module LEDs
Craft Pinout
PIN
NAME
1, 4, 6-9
N/A
2
RD
3
TD
5
SG
System Status LEDs
The System Status LEDs display the status of the power supply, controller, and
other system conditions for the ATLAS 550. For a more detailed discussion of
the front panel LEDs, refer to Section 2, Engineering Guidelines, of the ATLAS
550 System Manual.
LED
Description
Power
Indicates the status of the power supply.
System
Indicates the status of the unit controller and other system conditions.
Ethernet
Indicates the status of the Ethernet port.
Remote
Indicates whether a user (Telnet or VT100) is logged in to the unit.
port, and
P/N 1200550L2
DESCRIPTION
Not Connected
Receive Data (output)
Transmit Data (input)
Signal Ground
 2003 ADTRAN, All Rights Reserved
www.adtran.com