Commissioning
You will find further details in the "Software upgrade"
chapter in the appendix.
Note
A software upgrade via the web server may only be per-
formed by a Level4 type user.

Logging out from the wireless alarm system

Click the Log out button.
If you are working directly in the alarm control panel, click
the "Exit" menu key.
Important!
Saving the settings:
S/W <2.00.00
When you make these changes in the Installer Mode, the
Secvest stores these changes in temporary storage until
you leave the Installer Mode.
When you leave the Installer Mode, the alarm control
panel writes these changes to permanent storage.
If you power off the alarm control panel completely
BEFORE leaving the Installer Mode, the alarm control
panel will lose all your changes.
Please note that this does not apply if you restore the
factory defaults; this change is implemented immediately.
S/W >=2.00.00
When you make these changes in the installer mode,
they will be saved directly in the Secvest's permanent
storage following confirmation.
They will be preserved, even in the event of power failure
before you exit installer mode.
Important!
Automatic log out function:
Based on the Secvest's automatic log out function, this is
now also possible on the web interface and Secvest app.
Installer or level 4 user is logged into the web in-
terface. The automatic log out occurs after
1 hour of inactivity.
iOS/Android app: Once opened, the app closes
after 4:15 minutes have passed without an input
in accordance with the VdS 3169 standard,
providing "Remember PIN" is set to no.
o
44
Normal user or administrator is logged in. The
automatic log out occurs after 1 minute of inac-
tivity.
Important!
Time schedules active/inactive, week planner
Please inquire with the alarm panel user about a possible
programmed time schedule in the user menu.
If the alarm panel is in installer mode, planned events are
moved. They are NOT annulled.
Pending events are carried out when installer mode is fin-
ished.
This means that after leaving installer mode, the alarm
panel switches to the state desired and programmed by
the user for this time period.