Abus Secvest 2Way Operating Instructions Manual

Abus Secvest 2Way Operating Instructions Manual

Hide thumbs Also See for Secvest 2Way:
Table of Contents

Advertisement

Secvest 2Way
O P E R A T I N G I N S T R U C T I O N S
1
BOM-No 12000869

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Secvest 2Way and is the answer not in the manual?

Questions and answers

Summary of Contents for Abus Secvest 2Way

  • Page 1 Secvest 2Way O P E R A T I N G I N S T R U C T I O N S BOM-No 12000869...
  • Page 2: Preface

    This wireless alarm centre is used to secure your property in combination with detectors and transmitters. Among others, it can be used to protect your company Many thanks for your purchase of the SECVEST 2Way wireless alarm centre. This premises, house, garage, summer house or weekend cottage.
  • Page 3: Table Of Contents

    14. Resetting the alarm ................. 16 2. Contents 15. Alarm transmission by telephone ............. 17 Preface ......................2 16. Remote control by telephone ..............17 Introduction ...................... 2 17. User menu ....................18 2. Contents ...................... 3 18. Settings in the user menu ................ 19 3.
  • Page 4: Safety Information

    3. Safety information !WARNING! !Caution! !IMPORTANT! To avoid fire and injury, please note the following: Please observe the following precautionary measures On burglar alarm centres in general: to ensure trouble-free operation of your system. • Securely fasten the device in a dry location in the •...
  • Page 5: System And Keypad Overview

    4. System and keypad overview 1 – Chip key reader 2 – Graphic display Multiple-line display 3 – Integrated siren 4 – Activation button 5 – Deactivation button 6 – Control buttons 7 – Keypad alarm keys for panic, fire, medical and social call emergencies 8 –...
  • Page 6: Graphic Display

    5. Graphic display The graphic display informs you about all events concerning the wireless alarm system. The following is an overview of the different display messages and their meaning: The four black bars stand for the four This symbol appears if a voice message individual partitions of the wireless exists that should be listened to.
  • Page 7: Activating The Wireless Alarm System

    6. Activating the wireless alarm system The wireless alarm system can be activated in a variety of ways. The system emits an acoustic message. Depending on whether a partition or the complete system is activated, the message is: “Partition activated” or “Alarm system activated”. 6.1.
  • Page 8: During The Delay Time

    7. During the delay time Provided no errors that prevent activation have occurred (zone open), the wireless alarm system starts the configured exit delay time. The system emits an acoustic message. Depending on whether a partition or the complete system is activated, the message is: “Partition activated”...
  • Page 9: Notes On System Activation With Compulsory Hidden (Omitted) Zones

    Automatic omission with confirmation Using the control button, select the item under View to display the error. The following graphic display is shown: System is activated by: • Fast activation • Remote control • Arming station • Chip key • Wireless cylinder The following display is shown: The wireless alarm system now shows all zones that are open or have an...
  • Page 10: Delay Time Started

    8.3. Delay time started The following graphic display is shown after entry of the correct user code or immediately after the alarm is acknowledged: The alarm system starts the delay time, but with a pulsed tone instead of a continuous tone. This indicates that one or more zones are still open. Close these zones within the delay time so that a continuous tone is emitted again.
  • Page 11: Following Successful Activation

    9. Following successful activation When the alarm centre is successfully activated (also with automatically omitted zones), an acknowledgement is received after the delay time has expired. This acknowledgement can have different forms: • Acknowledgement tone on the wireless alarm system •...
  • Page 12: Deactivating The Wireless Alarm System

    10. Deactivating the wireless alarm system The wireless alarm system can be deactivated in a variety of ways: • Deactivation of the entire system or a partition with a user code • Deactivation of the entire system or a partition via remote control •...
  • Page 13: Activating Partitions

    11. Activating partitions If the alarm system is set up so that two or more partitions can be monitored independently of each other, these partitions can now be individually activated or deactivated. A user can now activate/deactivate one or more partitions, depending on the user authorisation. If the entire alarm system is activated, each partition is also activated.
  • Page 14: Internal Activation

    12. Internal activation In addition to monitoring one or more partitions (i.e. objects or company departments) separately, the system also has an internal activation option. This type of activation is often used to monitor the exterior of the object when it is still occupied. In this case, specific detectors within the object such as motion sensors are removed from surveillance.
  • Page 15: Alarms

    13. Alarms The wireless alarm system has three different types of alarm. Depending on the system state (deactivated, internally activated, activated) or triggered alarm zone (technical alarm, panic alarm, burglar alarm, fire alarm), one of the following alarms can be triggered: •...
  • Page 16: Resetting The Alarm

    “Warning! An alarm has been triggered. A system reset is 14. Resetting the alarm required.” If the alarm system has triggered an alarm (whether local, external or silent), The following graphic display is shown after entry of the correct user code or then this must first be acknowledged and then reset.
  • Page 17: Alarm Transmission By Telephone

    15. Alarm transmission by telephone 16. Remote control by telephone In addition to alarms from sirens and signalling devices, the wireless alarm The alarm centre can call you in the event of an alarm. After listening to the system can also transmit an alarm via telephone (PSTN, ISDN, GSM). There message, you can send commands to the system by pressing your telephone are two types of alarm transmission by telephone: keypad.
  • Page 18: User Menu

    The alarm centre registers the status of your commands through different 17. User menu tones: The user menu is graphically designed to be used almost intuitively. The Beep = Command accepted control buttons are used to navigate around the user menu. Beep, beep = Action carried out = Action failed...
  • Page 19: Settings In The User Menu

    18. Settings in the user menu Overview of menu items in the user menu 18.2. 18.1. First steps in the user menu Among other things, the user menu can be used to program the user code, omit zones, record voice messages, read the log, activate control functions In the user mode, proceed as follows: and test detectors.
  • Page 20: Recording Voice Messages

    If Select was confirmed using the control button, recording begins and the 18.3. Recording voice messages following graphic display is shown: The wireless alarm centre enables the user to record individual voice messages. These voice messages can be listened to and deleted at any time.
  • Page 21: Omitting Zones

    18.4. Omitting zones 18.5. Installing users If necessary, you can remove zones from surveillance (e.g. if a detector is As an administrator, you can use your code (master code) to install further defective or a zone cannot be closed). users for the wireless alarm system. Up to 50 users can be installed on the system.
  • Page 22: Editing Users

    18.5.1.1. Changing the user name 18.5.1. Editing users Select the user, then the “Name” menu item. After selecting the Edit User menu item, the user attributes can be edited. Remove the existing name by pressing Delete, then enter a new user name. Enter letters via the keypad.
  • Page 23 18.5.1.3. Defining partitions 18.5.1.2. Changing the user type User authorisations are defined in this menu. In this way, different users can control different partitions. The settings also refer to the chip key trained for this user. Select the user type: •...
  • Page 24 18.5.1.4. Changing the user code 18.5.1.5. Training and removing chip keys, remote controls, pendants and panic transmitters Select the Code menu item. Follow the instructions in the display to train the corresponding components to the wireless alarm system. The following page shows how to train the different components.
  • Page 25 Training the chip key Training the remote Training the remote Training the wireless Training the pendants control without panic control with panic cylinder (emergency call Select Tag. The system function (FU5155) function (FU5150) transmitters) prompts you to hold the chip Select Telecommands.
  • Page 26: Adding Users

    15.5.2. Adding users 15.5.3. Deleting users To add a new user to the wireless alarm system, select the Add User menu To delete a user and all user settings (such as remote controls and chip keys), item. select the Delete User menu item. Select the corresponding user by pressing Delete.
  • Page 27: Viewing The Log

    If Expanded was confirmed with the control button, the following graphic 18.6. Viewing the log display is shown: This function enables you to read the event log. This log contains the last 250 events together with the date and time. The log cannot be deleted. When the log is full, the oldest event is deleted to make room for a new event (FIFO memory).
  • Page 28 System Rearmed The system has automatically reactivated itself Low Battery The system battery is not charged. following an alarm. Low Batt Restore The battery error was confirmed. U-- Z== Omit User -- has omitted zone ==. Battery Load Fail The battery cannot be charged. Fire Z== Alarm Zone == has triggered a fire alarm.
  • Page 29: Additional Functions

    Function Meaning 18.7. Additional functions Chime When deactivated, the system emits a signal tone if a door chime detector is triggered. This signal tone In this menu, a user can switch the functions assigned to them by the installer can be deactivated here. on and off.
  • Page 30: Test

    Function Meaning 18.8. Test Siren Tests local alarms on the system and external sirens. Loudspeaker Tests the loudspeaker function. This menu is used to test the different alarm centre functions. Keypad Tests the keypad function. Walk Test Tests the functions of the individual zones. Outputs Tests the wired and wireless outputs.
  • Page 31: System Configuration

    Outputs 18.9. System configuration A list of all outputs installed on the system is shown on the display. Select the This menu is used to change individual system settings, such as date and output to be tested. Press Done to end the test. time, outputs and remote controls.
  • Page 32 About Comms Shows information on the available communication Function Meaning paths. Set Date & Time Select this point to enter the date and time of the Additionally, the following alarm centre information wireless alarm system. is displayed. Edit Outputs Select this point to change the times of the manual With inserted ISDN module: output.
  • Page 33: Week Planner

    18.9.1. Week Planner Only users with administration rights can install this function. The system should be activated and deactivated according to the time and day of the week. First create a weekly plan of the activation and deactivation times. Each day, up to 5 data records can be programmed for activation (start) and 5 data records can be programmed for deactivation (end). Monday Tuesday Wednesday...
  • Page 34: Activation / Deactivation Of The Week Planner

    18.9.2. Activation / deactivation of the week planner Access the user menu using the administrator code (default = 1234) and create a week planner. Access the menu and enter your access code. In the System Config menu, select the Auto Set/Unset menu item. Set (activated) Deactivation Activation Y...
  • Page 35: Auto Set

    18.9.4. Auto Set Select the time for Auto Set (00:00). Monday Tuesday Time 00:00 00:00 Data record 01:00 Activation 02:00 Select data record 1. 03:00 04:00 05:00 06:00 07:00 07:20 07:20 08:00 Select activated Y Select the activation time. 09:00 10:00 11:00 12:00...
  • Page 36: Auto Unset

    18.9.5. Auto Unset Monday Tuesday Select the time for the Auto Unset (07:20). Time 00:00 00:00 01:00 02:00 03:00 Select data record 1. 04:00 05:00 06:00 Data record Deactivation 07:00 07:20 07:20 08:00 09:00 Select activated Y Select the activation time. 10:00 11:00 12:00...
  • Page 37: Internal And External Activation

    18.9.6. Internal and external activation In this example, partition 1 is switched from internal activation (external perimeter protection) to external activation (completely activated). The system should have external perimeter protection from 18:00 onwards and a complete activation from 20:00 onwards. The change from internal to external activation cannot be made without an interruption of <...
  • Page 38: Activating And Deactivating Data Records

    18.9.6. Activating and deactivating data records To deactivate a data record (time period), make changes in the AUTO SET menu. In AUTO UNSET, change Set to N. Monday Tuesday Time 00:00 00:00 01:00 Data record 1 02:00 Data record: Data record: Tuesday 03:00 Start deactivated...
  • Page 39: Follow Me

    18.10. Follow Me 18.11. Outputs On/Off This menu is used for entering the follow me number. This number is dialled This menu is used to activate or deactivate individual outputs manually. to send a voice message to a telephone of your choice in the event of an Only outputs programmed as manual can be activated.
  • Page 40: Telephone Call

    19. Error displays 18.12. Telephone Call There are several errors that can occur during normal system operation. This menu is used to start a telephone call manually and test the telephone These errors do not immediately trigger an alarm or prevent system activation. line or GSM connection.
  • Page 41: Errors, Meanings, Causes And Suggested Solutions

    19.1. Errors, meanings, causes and suggested solutions Displayed error Meaning Possible causes Suggested solutions • • AC Fail The 230 V AC system The main fuse of the PSU on the wireless Replace the main fuse with one of the same power supply is missing.
  • Page 42 Displayed error Meaning Possible causes Suggested solutions • • Low Batt Z__ No battery power supply The battery capacity in the detector of zone Change the detector battery within 14 days. in zone __. __ is almost exhausted. • • WAM__ SUP Fail Supervision signal from The accessory module outside the wireless...
  • Page 43: Declaration Of Conformity

    20. Declaration of conformity The declaration of conformity to the applicable guidelines has been made available and signed by Security Center management. It is available under www.abus-sc.eu. 21. User menu overview...
  • Page 45 Amendments to the operating manual (UK) Secvest 2WAY FU8006 S/W ≥ 5.04.22 A1 -...
  • Page 46 We constantly develop our product range in order to provide our customers with optimal products incorporating state-of-the-art technology. The new software release for the Secvest 2WAY includes optimised workflows and an extended function range. These improvements can be found in the following document.
  • Page 47 Lock 4). The wireless cylinder functions can be tested here. “Unlocked” is shown on the Secvest 2WAY display when the door is unlocked. “Locked” is shown when the button on the Secvest Key 2WAY wireless cylinder is pressed and the door is then locked.
  • Page 48 3.2. FU8100 wireless remote control User Menu System Config Telecommands 2 Way Instant Set 2 Way Instant Set Y 2 Way Instant Set • “Y” (yes) is the default factory setting. The alarm centre is activated immediately when the FU8100 remote control is pressed.

Table of Contents