Appendix
SMS
Receiver
PSTN SMS protocols
Email
Receiver
Remote control by telephone
ATS Alarm transmission system
Categories and classifications
ATS (Alarm Transmission System) categories,
SPT (Supervised Premises Transceiver) clas-
sification
Classification of transmission time
Transmission time, maximum values
Classification of notification time
Classification of availability
Security to prevent removal
Information security
Monitoring a/b, Ethernet and GSM/wireless
mobile
Handshaking procedure
292
8
TAP 8N1
TAP 7E1
UCP 8N1
UCP 7E1
ETSI Protocol 1
8
Yes
The alarm panel contains an integrated SP2 (ATS2) communica-
tor to fulfil the requirements of EN 50131 for security level 2.
The alarm transmission system is compliant with EN 50136-
1:2012 as an SP2 (ATS2) communicator.
The alarm panel supports options A, B and C for grade 2 as given
in Table 10 in EN 50131-1:2006+A1:2009
D2 -> SP2
M2 -> SP2
T2 -> SP2
A0 (no requirement)-> SP2 (optional)
There is no method for achieving compliance with EN 50136-
1:2012, 6.7.3 (non-availability of the alarm transmission system)
because A0, no requirement.
S0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with EN50136-
1:2012, 6.7.2 (redundancy) because S0, no measures
I0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with EN 50136-
1:2012, 6.8.3 (information security) because I0, no measures.
See the Communication options chapter in the Installer manual.
Installer mode -> Communication -> Comm. options -> Comm.
path fault response
Ethernet, PSTN (a/b), GSM/mobile
Installer mode -> Communication -> Comm. options -> Comm.
path fault delay
Ethernet, PSTN (a/b), GSM/mobile
Mode/procedure:
Transfer
(EN 50136-2:2013 Section 6, Operation)