Abus SECVEST Installer Manual page 264

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Configuration
Function
Meaning
Door locks Testing of door locks is carried out in the web interface in the same manner as on the alarm panel.
Select the door lock to be tested.
Operate the corresponding door lock.
After unlocking, "Unlocked" appears on the display.
After locking, "Locked" appears on the display.
• Secvest key: press the button and then lock.
• Additional door lock: do not press the button. Then lock.
Note
You can check here whether DIP switch 3 in the Secvest key is correctly
set according to the door stop.
The received signal strength is also displayed.
The meaning of the number before and inside the brackets can be found
in the signal strength explanation.
Signal
This option can be used to check the received signal strengths of all wireless components of the system.
Strengths
Note
To ensure good wireless communication, you must have a signal strength greater than 3. During
the test, the reception power of the wireless alarm panel is reduced by 6 dB. The Secvest wireless
alarm panel is sensitive to approx. -110 dBm at a signal-to-noise ratio of 12 dB.
The following level values apply for the signal strength display on the Secvest:
0
1
2
3
4
5
6
7
8
9
The number before the brackets is the signal strength of the last received signal.
The number inside the brackets is the smallest signal strength received since the last reset.
The alarm panel records the received signal strengths, even if you do not see them in this menu.
S/W <2.00.00
The signal strength of the repeated signal from the WAM is the same as that from each WAM.
For this reason, use the display of the signal strength for the corresponding WAM in order to gain infor-
mation about the signal strength of the repeated signals from the wireless components.
S/W >=2.00.00
The signal strength of the direct signal from each component is displayed in the right-hand column (WEB
column direct).
The signal strength of the repeated signal from the WAM or the RF repeater is displayed in the left-hand
column (WEB column repeater).
Resetting signal strengths to begin a new measurement.
WEB
Click on the line for the desired component and follow the instructions on the screen.
Click on "Reset ALL" and follow the instructions on the screen. This will clear the recorded signal
strengths for the entire list.
264
< −101 dBm
< −98 dBm
< −95 dBm
< −92 dBm
< −89 dBm
< −86 dBm
< −83 dBm
< −80 dBm
< −77 dBm
≥ −77 dBm