Appendix

CID/SIA Events

This menu only appears if you select "Contact ID" or one of the SIA versions at the following point:
Installer Mode -> Communication -> ARC Reporting -> Protocol
A detailed description of the CID and SIA formats can be found in the "ARC (ESCC) reporting protocol formats" ap-
pendix
To simplify the programming, the possible CID/SIA events are assigned to corresponding groups. In Table 1 and 3,
you can see the CID/SIA events with the corresponding group assignment. In Table 2 and 4, you can see the groups
with the corresponding CID/SIA events.
If you approve a group using "Yes", the alarm control panel can send every event from this group.
Notes:
CID/SIA alarm transmissions require significantly more time than Scancom Fast Format as the system transfers ex-
tended alarm data to the alarm receiving centre (ARC, ESCC).
Note
The alarm control panel delays the ARC reporting and entering in the log book by approx. 15-22 minutes (randomly),
either in the event of a mains failure (power cut) or when leaving the Installer Mode with an existing mains failure
(power cut).
The alarm control panel delays the ARC reporting and entering in the log book by approx. 60-90 seconds (randomly),
either once the power supply is restored or when leaving the Installer Mode and the power supply is restored.
344