Function
Meaning
Emer-
Testing of the nursing emergency call function is carried out in the web interface in the same manner as
gency call
on the alarm panel.
Nursing emergency call must be activated and the contact must be saved in the phone book.
Installer Mode->Communications->ARC Reporting ->Call Mode ->Single
(or Alternate)
A list of the available connected transmission paths can be seen:
PSTN
• When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient 2) are dis-
played with their contact names as stored in the phone book.
• Scroll to the desired contact. Press the "Select" or "Start" key in the web interface.
• The alarm panel sends a test call to this recipient.
• The event (or trigger) "Test" is sent according to the set protocol.
GSM / Mobile
• When this is selected, the 2 possible configured recipients (Tel Recipient 1, Tel Recipient 2) are dis-
played with their contact names as stored in the phone book.
• Scroll to the desired contact. Press the "Select" or "Start" key in the web interface.
• The alarm panel sends a test call to this recipient.
• The event (or trigger) "Test" is sent according to the set protocol.
During the test call a series of progress messages appear on the display.
If the test call was not successful, the display shows a brief message with the
cause of the error.