Configuration
Note
It is possible to select a different type of wiring for the
alarm panel and for each of the 2 hybrid modules.
Possible wiring types:
2-wire FSL 2k2/4k7
2-wire FSL 1k/1k
2-wire FSL 2k/2k
2-wire FSL 4k7/4k7
4-wire CC
2-wire CC
The variants are the same as for the alarm panel, see
also:
System -> Hardware -> Wired Zone Type
Loudspeaker partitions
Select the partitions for which the optionally connected
loudspeaker should provide a signal.
Note
The loudspeaker repeats the signal tones:
You can set the volume of the different signal tones for
the loudspeaker in the user menu.
User menu -> Configuration -> Volume settings ->
Operator Sounds
Info tones:
Alarm tones:
Note
Loudspeaker partitions for the hybrid module can be as-
signed to other partitions but they should be hybrid mod-
ule partitions.
Note
Zones
Zone types and attributes
102
Are selected in the HyMo Zones section. All availa-
ble types and attributes for wired zones are
possible. See IP Zones for details.
Hybrid module 1
401 to 410 where 2-wire is chosen as the
zone type
401 to 405 where 4-wire is chosen as the
zone type
Hybrid module 2
411 to 420 where 2-wire is chosen as the
zone type
411 to 415 where 4-wire is chosen as the
zone type
Note
Outputs
Output types and attributes
Are selected in the HyMo Outputs section. All
available types and attributes for wired outputs
are possible. See Wireless Outputs for details.
Hybrid module 1
401 to 404
Hybrid module 2
405 to 408
Note
Hybrid module TR terminal
If this input is controlled by the hybrid module,
the alarm panel signals
"Hybrid Module X Sounder Tamper"
Note
Hybrid module terminal MAINS FAIL