Configuration
Function
Meaning
Zone Re-
The current resistances for the wired zones (alarm panel and hybrid module) are displayed here.
sistances
Display on the alarm panel:
The zone names are displayed. To view the zone numbers, press the right menu key.
Test all variants according to the type of wiring to determine whether they meet the requirements:
• Alarm contact open/closed
• Tamper contact open/closed
• Short circuits
• Open (isolated circuits)
0k00 means 0 ohms or NC
Note
"4-wire CC" wiring type
Alarm panel
The display switches between the resistance of the alarm loop (A) and the resistance of the
tamper loop (S).
WBI
Here the field shows both values simultaneously, the resistance of the alarm loop (A) and the re-
sistance of the tamper loop (S).
Example for a "2-wire FSL 2K2/4K7" zone
• Alarm contact closed (standby)
• Alarm contact open
• Alarm contact open and series resistor bridged
• Short circuit in line to detector
• Line disconnection
Panel PSU Here you can find information about the voltage values of the power supply. The display is identical on
the alarm panel and the web interface.
Ext. DC voltage in
• The voltage value of the external DC power source
Panel Battery 1
• The voltage value of the first battery
Panel Battery 2
• The voltage value of the second battery
Aux. Voltage Out
• The voltage value at the terminal clamp 0 V/12 V AUX
Example (battery 2 is not connected in this example)
272
2k18
6k89
4k68
0k00
NO