Aux power supply output fault triggered at
Surge protection trip voltage
PSU monitoring
Fuses
Mains fuse (AC in)
Name
Characteristic
Operating current
Breaking capacity
Operating voltage
Design
Running on DC input
@13.0V
12.8 V max, idle
12.2 V min, full load (@ 600 mA)
@13.8V
13.6 V max, idle
13.0 V min, full load (@ 600 mA)
@14.5V
14.3 V max, idle
13.7 V min, full load (@ 600 mA)
Note
This output is not buffered by the battery in case of power failure.
The output voltage during a power failure is directly 0 V.
11.5V
OK from 12.0 V
Not given for grade 2
Monitoring covers AC and external DC faults.
It notifies the alarm panel if the AC or external DC power sup-
ply is disrupted or fails. The alarm panel will continue running
on the batteries but the alarm panel and user are informed.
Monitoring covers battery under voltage.
If the battery is flat, the alarm panel and user are informed and
the alarm panel gives a warning.
Miniature fuse (micro fuse)
removable
T1AL250V
T = slow blow
1 A
L = low
250 V
Glass tube 5x20 mm