Abus SECVEST Installer Manual page 263

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Function
Meaning
Wireless
Testing of wireless control panels is carried out in the web interface in the same manner as on the alarm
control
panel.
panel
Press the function buttons on the wireless control device one after the other.
Wait 2 to 3 seconds between each button so that the control device can send each message.
A corresponding letter appears on the display in response:
A = "arm" button (closed lock)
C = "internal arm" button (*)
D= "query status" button (?)
B = "disarm" button (open lock)
On the Web you will also see:
Arm system key
Arm system internally key
Status query
Disarm system key
To test the number buttons, press 4 or 6 numerical buttons (corresponding to the set code length) and
then a function button: Example:
• Press
• Displayed
Press the dual keys (fire alarm, hold up alarm, medical emergency or social care alarm) at the same time
to test them. On the display:
F = dual keys fire alarm
P = dual keys hold up
M = dual keys medical emergency
H = dual keys social care alarm
On the Web you will also see:
Fire key
Intrusion key
Medical emergency call key
Social Care Key
The lower "*" and "#" button on the control device cannot be tested.
: 1234?
: 1234D (status query)