Abus SECVEST Installer Manual page 101

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Delete All
Add hybrid module (alarm panel)
1.
Select Hybrid Module.
2.
Select Add/Del.
3.
Select the corresponding hybrid module.
4.
Trigger the tamper contact of the hybrid module.
Note
When a hybrid module has been taught in, the
wireless alarm panel beeps twice to confirm this.
A message appears on the display to confirm the
hybrid module has been added, and the value for
the received signal strength is shown.
5.
Exit the entry with Back.
Note
If a hybrid module has been taught in, the symbol
appears next to the hybrid module number on
the alarm panel display
A maximum of 2 hybrid modules can be added
6.
Exit this display with Back.
Edit
The following course of action is the same as is described for the alarm panel's
menu guidance below.
Click on this field and in the next step confirm the security prompt to delete all hy-
brid modules with Yes. Select Back if you are not sure.
Select the corresponding hybrid module.
The following sub-menu items appear.
Name:
Assign a unique name to this hybrid module.
Partitions
Numbers of the partitions to which the hybrid module is
assigned.
Note
Refer to the assignment of partitions for the hybrid mod-
ule. Notifications from the hybrid module, such as tamper
or DC fault notifications, are then assigned to these parti-
tions.
Hybrid module zones and outputs can be assigned to
other partitions but they should be hybrid module parti-
tions.
Wired Zone Type
Select which wiring type should be supported for the
zone inputs of this hybrid module.
Configuration
101