Configuration
Type
Explanation
disabled when the wireless alarm panel is armed or disarmed. If the "Chime" attribute is assigned
to this zone, the doorbell sounds both when the wireless alarm panel is armed and disarmed.
Lock Set
This zone is used to cancel the exit delay for a partition with the "Lock Set" attribute. This zone type
is typically used for a switch (NO). Note: this zone is enabled during the exit time and when the
wireless alarm panel is armed. This zone can be assigned to the "Inverted" attribute.
Ext WD Fault
This zone is used to monitor the fault output of external sounders. If a fault output with this zone
type is triggered, "Ext WD Fault" appears on the display. This zone type is not available for wireless
zones.
HUD Fault
This zone is used to monitor the fault output of wired hold up signalling devices. If a hold up device
with this zone type is triggered, "HUD Fault" appears on the display. This message also appears on
the display if the user tries to arm the wireless alarm panel while an alarm is active. The user can
override the fault and arm the system. If this fault is triggered while the system is armed, a log book
entry is created and the communication configured accordingly is started, but no alarm is triggered
until the wireless alarm panel is disarmed. This zone type is not available for wireless zones.
Tamper Return
This zone is used to monitor the tampering output of external sounders. Monitoring of this zone is
permanently enabled. If a zone with this type is triggered when the wireless alarm panel is dis-
armed, only the internal siren is activated. If this alarm is triggered when the system is armed, the
communication can be sent if configured accordingly and external sounders with strobe can be trig-
gered. This zone type can have the following attributes: "Soak Test", "Part Set", "Omittable" and
"Force Set". This zone type is not available for wireless zones.
Ext PSU A/C
This zone is used to monitor the AC fault output of an external power supply. If a zone of this type
fault
is triggered, the wireless alarm panel reacts as if there were a "Panel A/C fault" on the panel itself.
The response depends on the configuration. This zone type is not available for wireless zones.
Ext PSU Batt
This zone is used to monitor the battery-fault output of an external power supply. If this fault is trig-
Fault
gered, outputs configured for "Battery Fault" are activated and "Ext PSU Batt Fault" appears on the
display. If this fault is triggered while the system is armed, a log book entry is created and the com-
munication configured accordingly is started, but no alarm is triggered until the wireless alarm panel
is disarmed. This zone type is not available for wireless zones.
This zone is used to monitor a fault output for "low battery" of an external power supply. If this fault
Ext PSU Low
Volts
is triggered, outputs configured for "Low Volts" are activated and "Ext PSU Low Volts" appears on
the display. If this fault is triggered while the system is armed, a log book entry is created and the
communication configured accordingly is started, but no alarm is triggered until the wireless alarm
panel is disarmed. This zone type is not available for wireless zones.
Ext PSU Fault
This zone is used to monitor the fault output of an external power supply. If this fault is triggered,
outputs configured for "Ext PSU Fault" are activated and "Ext PSU Fault" appears on the display. If
this fault is triggered while the system is armed, a log book entry is created and the communication
configured accordingly is started, but no alarm is triggered until the wireless alarm panel is dis-
armed. This zone type is not available for wireless zones.
Only enabled
This zone is used to ONLY ENABLE the alarm panel for access control and home automation ap-
plications. With this zone, the alarm panel CANNOT BE DISARMED due to EN 50131 and VdS re-
quirements.
Clear user authentication or user identification is not always available in home automation.
An output of an access control or home automation application can be connected to the burglar
alarm system.
A change to this zone changes the status of the alarm panel from Disarmed to Enabled (in accord-
ance with the programmed output mode).
Note
Please note that the access control or home automation application in this zone must be closed
again after a specified period (but > 400 ms). When the status is not known, e.g. when the zone is