informs about the signal strength and quality in 3G
if the current supplying wireless mobile cell is not a 3G cell, then it will read 255
e, f
informs about the signal strength and quality in 4G
if the current supplying wireless mobile cell is not a 4G cell, then it will read 255
Value range
e = quality , 0 (very poor) – 34 (very good)
f = signal strength, 0 (very poor) – 97 (very good)
X = 1 = Email
See above
X = 2 = VoIP SIP
See above
X = 3 = Telephone call
See above
X = 4 = HTTPS client
See above
X = 5 = HTTPS server
See above
X = 6 = SIA-IP (DC-09)
The communication protocol between the alarm control panel and ARC/ESCC. The actual DC-09 messages
are listed in ASCII notation. The display of the DC-09 messages is similar to that in the examples in chapter
"Appendix B: Example Message Frames" of the DC-09 specification.
>A38700b6"*SIA-DCS"0013L0#7128[c499a115.......]....
Note
As required for DC-09, time stamps refer to GMT.
X = 7 = SNTP
The communication protocol between the alarm control panel and the NTP server.
Example
>***Timesync from ntp.exnet.com***
X = 8 = PPP
Point-to-Point Protocol
Mainly for mobile transmission
Example
>ATDT*99***1H
<CONNECT
tone dialling
X = 9 = Cloud Connection
The communication protocol between the alarm control panel and the ABUS cloud.
Example:
>Panel ID: U0yVq7k.....
X = 10 = System (S/W >= v3.01.01)
10 = Press the ▲ "Up" menu key
This view displays system errors
X = 11 = cameras (S/W >= v3.01.09)
Appendix