Note
The Soak Test function should only be
set if a detector tends to trigger false
alarms.
This function works automatically. To test
the range of the detector, use the "walk
test" function and do not activate the soak
test, as this function stops the detector
from triggering any alarms when the
wireless alarm system is armed and
only saves a message to the memory in-
stead.
After 14 days the wireless alarm system
resets the zone and brings it back to nor-
mal operation.
Part
This zone is monitored when the partition
Set
of this zone or all partitions are internally
armed.
Activity
The function of the detector is reversed
Mon.
(inverted). This should only be used in
connection with the social care emer-
gency call.
An alarm is triggered on the alarm panel
when the detector does not register any
alarm within a certain time period.
Inverted
Only in wired zones
Switches the behaviour of the indicator.
Closed = alarm
Open = no alarm
Configuration
77