Abus SECVEST Installer Manual page 352

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Appendix
Table 4 SIA report groups – SIA codes
SIA report group
Fire
Panic alarm
Panic alarm
Panic alarm
Medical Alarm
Medical Alarm
Intruder alarm
Intruder alarm
Intruder alarm
Intruder alarm
Technical Alarm
Tampers
Tampers
Set/Unset
Set/Unset
Set/Unset
Set/Unset
Part set
Part set
Reset
352
SIA code
Contains:
FA, FR
Fire Alarm and Fire Restore
HA, HR
Duress and Restore
HV
Hold Up (Panic) alarm acknowledged
PA, PR
Hold Up zone (Panic) and Restore
Hold Up keypad (Panic) and Restore
Hold Up RF (Panic) and Restore
Hold Up wireless control panel (Panic) and Restore
MA; MH
Medical alarm and Restore
QA, QH
Social Care (Social Emergency)
BA, BR
Intrusion Alarm and Intrusion Restore
BA, BR
Perimeter and Perimeter ok
Entry attempt and glass breakage e.g. of FTSE
BC
Alarm Abort
BV
Alarm confirmation
UA, UR
Technical alarm and Restore
Yes
4 incorrect User Codes entered one after the other (also known as "User
Code Tampering")
TA, TR
Keypad tampering and Restore
Detector tampering and Restore
Alarm control panel housing front tampering and Restore
Bell tampering and Restore
Wireless control panel tampering and Restore
External Sirens tampering and Restore
WAM tampering and Restore
Control panel tampering and Restore
Door Lock tampering and Restore
CA, OA
Schedule arming, schedule disarming
CE
Schedule arming delayed
CL, OP
System or partition armed and disarmed
CS, OS
System or partition armed and disarmed with key switch
CL
System or partition armed internally
CS
System or partition armed internally with key switch
OR
System or partition reset

Advertisement

Table of Contents
loading

Table of Contents