Name/function
RF Supervision
Camera supervision
168
When the numerical codes are reset (from 6 to 4 digits), all users and in-
stallers are reset to their factory defaults (remote controls, chip keys, etc.,
are also deleted)
Explanation (checkbox)
Dropdown selection field for alarm system response for RF supervision
If a wireless detector has had no contact with the alarm control panel for more than
20 min, the alarm panel creates a log entry: "RF warning". The alarm panel also
prevents the system from being armed. If a user overrides this warning and arms
the alarm panel, the log entry "RF warning overridden" is generated.
If a wireless detector has had no contact with the alarm panel for more than 2 h,
corresponding processes are activated as follows:
Alarm panel is armed
Disabled
No response
• Log book entry of this event
Fault
• No display and no warning
tones
• "RF Supervision" or "RF Fault"
outputs are activated
• Supervision is reported
• Log book entry of this event
Tamper Ac-
• Tampering alarm
tivated
• Supervision is reported
Note:
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Note
The "Tamper" option is required in Grade 2 systems in order to comply with
EN 50131-1:2006+A1:2009
If the "Tamper" option is used along with the following setting:
System -> User Reset -> System Tampers = No
the user cannot reset the system.
Dropdown selection field for alarm system response for IP camera supervi-
sion
If a camera has had no contact with the alarm panel for longer than the reaction
time, the alarm panel creates a log entry and indicates a warning (e.g. IP Zone
Missing, IP-Zone Timeout).
For reaction time, see:
Components -> IP zones -> Add/delete -> Reaction time
Corresponding processes are activated as follows:
Alarm panel is armed
Alarm panel is disarmed
No response
• Log book entry of this event
• Display and warning tones
• "RF Supervision" or "RF Fault"
outputs are activated
• Supervision is reported
• Log book entry of this event
• Tampering alarm
• Supervision is reported
Note
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Alarm panel is disarmed