Basic Melter Operation
4-4

Starting the Melter for the First Time

Figure 4-2
Location of the drain chute and the drain valve
Part 1128350_02
Before starting the melter for the first time, confirm that the melter is fully
installed, including hoses and applicators, and any optional equipment.
1. Switch the melter On. See figure on the left for the melter power switch
location.
NOTE: The melter goes through a self-check, and after all the LEDs and
indicators briefly illuminate, the Commissioning Setup Wizard starts.
Refer to Commissioning Setup Wizard given in the following page.
2. Fill the tank with adhesive and wait a few minutes until enough has
melted to purge the air from the new pump.
3. Remove the front panel of the melter by loosening the four latches.
4. See Figure 4-2. Lower the drain valve chute and open the drain valve.
5. Set the pump air pressure to 1.03 bar (15 psi).
6. Press
on the OLED user interface to enable the pump.
7. Allow adhesive to flow from the drain valve until there are no air bubbles
present.
8. Close the drain valve.