Problem
5.
Pump leaks air from the
exhaust ports
6.
Pump leaks air from
between the air cylinder
and cylinder head
7.
Pump leaks air from
between the air cylinder
and pump frame
8.
Pump leaks air from
between the piston shaft
and the underside of the
air motor
9.
Pump leaks air from
between the air cylinder
and the actuator
assembly
E 2020 Nordson Corporation
Possible Cause
Missing or damaged O-rings on valve
assembly
Loose air piston assembly
Damaged or missing air piston cups
Missing or damaged O-ring
Loose cylinder screws
Missing or damaged O-ring
Loose cylinder screws
Air motor piston shaft seal missing,
worn, or damaged
Missing or damaged O-rings
Loose screws holding the actuator as-
sembly to the air cylinder
SP Pump Diagnostics and Repair
Corrective Action
Remove the valve assembly and replace
the O-rings.
Inspect and repair the air piston
assembly.
Replace the O-ring.
Tighten the screws to 25 – 31 in-lbs.
Replace the O-ring.
Tighten the screws to 25 – 31 inch lbs.
Replace the air motor piston shaft seal.
Replace the O-rings.
Tighten the screws.
B-5