Output Parameters

Selection
Disabled
Output not used
Temperature Ready
All temp zones within 5 °F set point, no faults or alerts,
system not in setback, ready delay complete
System Run-Ready
System State = Run (Temp Ready, Pump On, Patterns
Enabled)
Fill Ready
Fill system is enabled and no fill faults
Temperature
Temp Ready and Pump On conditions met (Does not
Ready-Pump On
include other subsystems such as fill, flow or pattern) - for
legacy support
Fill Active
Active fill signal causes output active
Fill Overfill Alarm
Max Fill time exceeded (overfill alarm) causes output
active
Fill Stop
Fill system stop causes output active
Tank Low
Adhesive level in tank low causes output active
System Alert
Any active system alert causes output active
NOTE: System Alert and fault are inverted and the
check-box is selected. The invert check-box is
automatically selected on factory reset.
System Fault
Any active system fault causes output active.
NOTE: System Alert and fault are inverted and the
check-box is selected. The invert check-box is
automatically selected on factory reset.
High Flow Alert
Flow Monitor related alert causes output active when
above the alert limit
Low Flow Alert
Flow Monitor related alert causes output active when
below the alert limit
High Flow Stop
Flow Monitor related stop causes output active when
above the stop limit
Low Flow Stop
Flow Monitor related stop causes output active when
below the stop limit
Part 1128350_02
Table 3-5 Output Parameters
Functions
Hardware Option Required
N/A
N/A
N/A
Fill System
N/A
Fill System
Fill System
Fill System
Level Sensor (Basic/Legacy)
N/A
N/A
Flow Board and License
Flow Board and License
Flow Board and License
Flow Board and and License