E 2020 Nordson Corporation
1
2
Figure 6-6
Accessing components
1. RTD
2. Thermostat
See Figure 6-6.
4. To remove the RTD:
Loosen the two screws that secure the retaining plate, and then slide the
RTD out from under it.
5. To remove the thermostat:
Remove the rubber boot, disconnect the wires, and then remove the two
screws.
6. To remove the level sensor:
Remove the four or six retaining nuts, and then remove the level sensor
and gasket from inside the tank.
Troubleshooting
3
3. Level sensor location (inside
the tank)
Part 1128350_02
6-23